Indian J Ophthalmol ; 2022 Mar; 70(3): 1037-1041
Article | IMSEAR | ID: sea-224216

ABSTRACT

During pandemic, eye banks worldwide faced drastic reduction of corneal retrieval. Since precut tissues are uncommon in India, the onus is on corneal surgeons to maximize the donor corneal usage. The stumbling block making the stromal part unusable in the graft preparation of the Descemet membrane endothelial Keratoplasty is the stromal window creation to place the orientation mark on the stromal side of the folded graft. To overcome this, we simply marked directly on the folded Descemet graft, after partly stripping it from the donor cornea. Then, we unfolded, punched, and created two grafts after completely stripping it, retaining the Descemet part for the endothelial Keratoplasty and the stromal part for lamellar Keratoplasty. Initially, we used a special F marker, and later we marked an L using just a spatula. This simple technique needing no extra donor tissue or instrumentation maximizes the tissue utility with proper patient selection.